Product Parameters
Output: | Profibus-DP(EN-50170) |
Measuring length: | 25~5500 mm,customized according to customer needs |
Repeat accuracy: | <±0.001% of full scale, minimum ±1µm |
Non-linearity: | <±0.01% of full scale, minimum ±50µm |
Operating voltage Ub: | +24Vdc ± 20% |
Ambient temperature: | -40°C ~+85°C |
Mechanical configuration: | Fastening M20 threads, Fastening M18 threads, Fastening 3/4" threads |
Housing material: | Aluminum alloy |
IP rating: | IP67 |
Approval/Conformity: | CE |
Product Description
The DP output magnetostrictive sensor meets the Profibus-DP (EN 50 170) protocol. The sensor transmits the absolute position data of the magnet ring to the controller in the form of RS-485 standard serial asynchronous, and the maximum transmit rate can reach 12Mbps. The Profibus-DP interface provides powerful diagnostic and setting functions in the form of GSD data sheets.
Installation Instructions
RH series pressure-resistant rodshell, built-in installation design for hydraulic system, pressure-resistant 35MPa continuous, flexible and simple installation mode, mounting thread form M18×1.5 or M20×1.5 or 3/4"-16UNF-3A.
Note: The measurement Non-usable area shown in the figure indicates that the output value of the sensor in this area is zero or unreliable. The default values of the first and last measurement Non-usable areas of this product are 50.8mm and 63.5mm respectively. The value of the measurement Non-usable area can be appropriately modified according to the needs of customers, please pointed out when ordering.